MIL-PRF-55310/11G
TABLE I. Dash numbers and operating characteristics.
Dash
Output
Supply
Input
Output voltage
Rise
Duty
Frequency-temperature
num-
frequency
voltage
current
and
cycle
tolerance (ppm)
-55C
-55C
-20C
ber
range
(max)
Logic: 1
Logic: 0
fall
(min)
(max)
times
to
to
to
+125C
+105C
+70C
(max)
A
B
C
MHz
V dc
mA
V dc
V dc
ns
percent
50
40
25
01
.05 through 6
+15
35
13
2
30
45 to 55
50
40
25
02
6 through 10
+15
40
13
2
30
45 to 55
50
40
25
03
.05 through 6
+12
25
10
1
60
45 to 55
50
40
25
04
6 through 10
+12
30
10
1
60
45 to 55
50
40
25
05
.05 through 6
+10
20
9.5
0.5
60
45 to 55
50
40
25
06
6 through 10
+10
20
9.5
0.5
60
45 to 55
Frequency-voltage tolerance: 1 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70C 0.2C at intervals of not more than every 72 hours for a
minimum of 30 days.
0.1 ppm per 30 days, maximum.
0.5 ppm per 90 days, maximum. 2/
5 ppm per year, maximum. 2/
Terminal strength: Method 211 of MIL-STD-202, test condition C.
Applied force: 2 pounds each terminal.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
Nonoperating: Test condition D.
Operating: Not required.
Ambient pressure:
Nonoperating: In accordance with MIL-PRF-55310.
Operating: Method 105 of MIL-STD-202, test condition C.
2/
This if a performance requirement of the oscillator. Support data shall be presented to the qualifying activity
showing that this requirement shall be met.