MIL-PRF-3098/3G
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 0.8 MHz to 20 MHz, inclusive.
Frequency tolerance: ±50 parts per million (ppm).
Equivalent resistance: See table I.
Antiresonance, load capacitance: 32.0 pF ±0.5 pF.
Mode of oscillation: Fundamental.
Operating temperature range (noncontrolled): -55°C to +105°C, inclusive.
Rated drive level: 1.0 mW, maximum.
Capacitance, shunt: 7 pF, maximum.
Shock (specified pulse):
Frequency change permitted: 0.8 MHz to 2.0 MHz: ±10 ppm
2.0+ MHz to 20 MHz: ± 5 ppm
Equivalent resistance change permitted: 0.8 MHz to 2.0 MHz: ±15 percent
2.0+ MHz to 20 MHz: ±10 percent
Thermal shock:
Frequency change permitted: 0.8 MHz to 2.0 MHz: ±10 ppm
2.0+ MHz to 20 MHz: ± 5 ppm
Equivalent resistance change permitted: 0.8 MHz to 2.0 MHz: ±15 percent
2.0+ MHz to 20 MHz: ±10 percent
Vibration: Method 201 of MIL-STD-202.
Frequency change permitted: 0.8 MHz to 2.0 MHz: ±10 ppm
2.0+ MHz to 20 MHz: ± 5 ppm
Equivalent resistance change permitted: 0.8 MHz to 2.0 MHz: ±15 percent
2.0+ MHz to 20 MHz: ±10 percent
Low temperature storage:
Resistance: See table I.
3