MIL-PRF-55310/8J
TABLE I. Dash numbers and operating characteristics.
Output voltage
Rise
Supply
Input
Dash
Output
Duty
Frequency-temperature
voltage
current
number
frequency
and
cycle
tolerance (ppm)
-55C
-55C
-20C
(max)
range
fall
at 1.4 V
Logic: 1
Logic: 0
times
(min)
(max)
to
to
to
+125C
+105C
+70C
(max)
A
B
C
V dc
mA
ns
percent
50
40
25
01
1 kHz to
+5
158
15
45 to 55
0.25
150 kHz
50
40
25
02
150 kHz to
+5
94
15
45 to 55
0.25
300 kHz
50
40
25
03
300 kHz to
+5
94
15
45 to 55
0.25
600 kHz
50
40
25
04
600 kHz to
+5
50
2.4 V dc
0.5 V dc
15
45 to 55
0.25
at 400A
2.5 MHz
at 16 mA
50
40
25
05
2.5 MHz to
+5
50
source
sink
15
45 to 55
0.25
5 MHz
50
40
25
06
5 MHz to
+5
35
15
40 to 60
0.25
10 MHz
50
40
25
07
10 MHz to
+5
25
15
40 to 60
0.25
20 MHz
50
40
25
08
20 MHz to
+5
35
5
40 to 60
0.25
30 MHz
50
40
25
09
30 MHz to
+5
50
5
40 to 60
0.25
50 MHz
50
40
25
10
50 Hz to
+5
158
15
40 to 60
0.25
1 kHz
Frequency-voltage tolerance: 2 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70C 0.2C at intervals of not more than every 72 hours for
30 days minimum.
5 Hz to 4.9 MHz
5MHz to 50 MHz
1 ppm per 30 days, maximum.
2 ppm per 30 days, maximum
4 ppm per 90 days, maximum
2 ppm per 90 days, maximum. 2/
10 ppm per year, maximum
5 ppm per year, maximum. 2/
Terminal strength: Method 211 of MIL-STD-202, test condition A.
Applied force: 2 pounds each terminal for 10 seconds.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
2/ This is a performance requirement of the oscillator. Support data shall be presented showing that this
requirement shall be met.