MIL-PRF-55310/13J
TABLE I. Dash numbers and operating characteristics.
Dash
Output
Supply
Input
Output voltage
Rise
Duty
Frequency temperature
num-
frequency
voltage
current
and
cycle
tolerance (ppm)
-55C
-55C
-20C
ber
range
(max)
fall
Logic: 1
Logic: 0
times
(min)
(max)
to
to
to
+125C
+105C
+70C
(max)
A
B
C
V dc
mA
ns
percent
100
70
55
01
300 Hz to
+15
40
13
2
30
45 to 55
6 MHz
100
70
55
02
6 MHz to
+15
40
13
2
30
45 to 55
10 MHz
100
70
55
03
300 Hz to
+12
30
10
1
60
45 to 55
6 MHz
100
70
55
04
6 MHz to
+12
30
10
1
60
45 to 55
10 MHz
100
70
55
05
300 Hz to
+10
20
9.5
0.5
60
45 to 55
6 MHz
100
70
55
06
6 MHz to
+10
20
9.5
0.5
60
45 to 55
10 MHz
Frequency-temperature tolerance (one-half temperature cycle, referenced to frequency measured at +23C
1C, immediately prior to starting of the test): See table I. Measurements taken at ten equally spaced
increments over the specified operating temperature range. 1/
Frequency-voltage tolerance: 1 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70C 0.2 C at intervals of not more than every 72 hours for a
minimum of 30 days.
0.5 ppm per 30 days, maximum.
2 ppm per 90 days, maximum. 2/
10 ppm per year, maximum. 2/
Terminal strength: Method 211 of MIL-STD-202, test condition C.
Applied force: 2 pounds each terminal for 10 seconds.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
Nonoperating: Test condition D.
Operating: Not required.
1/ For the purpose of transitioning this device to MIL-PRF-55310, `Frequency stability versus temperature' has been
renamed `Frequency-temperature tolerance'. The verification requirements of `initial frequency-temperature
accuracy (one-half temperature cycle)' shall apply except that frequency measurements shall be referenced to
the frequency measured at +23C 1C (fref) instead of to the nominal frequency (fnom).
2/ This is a performance requirement of the oscillator. Support data shall be presented to the qualifying activity
showing that this requirement shall be met.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business