MIL-PRF-3098/99E
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50 MHz to 125 MHz, inclusive.
Capacitance, shunt: 7 pF, maximum.
Frequency tolerances:
Operating temperature range: ±10 ppm.
Reference temperature: ±10 ppm.
Room temperature: ±80 ppm.
Frequency stability: ±5 ppm.
Mode of oscillation: Fifth mechanical overtone.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Reference temperature: +85°C ±1°C.
Temperature ranges:
Operating (controlled): +80°C to +90°C, inclusive.
Operable: +55°C +80°C, inclusive.
Equivalent resistance:
MHz
Ohms, max
50 to 100
50
100 to 125
60
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent
Vibration: Method 201, MIL-STD-202.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
Reference documents. In addition to MIL-PRF-3098, this document references the following:
The margins of this specification sheet are marked with vertical lines to indicate where changes from the
previous issue were made. This was done as a convenience only and the Government assumes no
liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to
evaluate the requirements of this document based on the entire content irrespective of the marginal
notations and relationship to the last previous issue.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business