MIL-PRF-3098/85D
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 10 MHz to 11.5 MHz, inclusive.
Frequency tolerances:
Operating temperature range: ±0.002 percent.
Reference temperature: ±0.002 percent.
Room temperature: ±0.008 percent.
Frequency stability: ±0.0005 percent.
Mode of oscillation: Fundamental.
Reference temperature: 85C ±2C.
Temperature ranges:
Operating (controlled): +80C to +90C, inclusive.
Operable: -55C to +80C, inclusive.
Capacitance, load: 32.0 pF ±0.5 pF.
Rated drive level: 1.0 mW, maximum.
Calibration values:
Resistance: 11 ohms.
Crystal current: 15 mA.
Capacitance, shunt: 7 pF, maximum.
Equivalent resistance: 22 ohms, maximum.
Frequency change permitted: ±0.0004 percent.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 201, MIL-STD-202; double amplitude .036 inches (0.91 mm) or 10 gravity units,
whichever is the limiting value. Frequency shall be cycled between 10 Hz and 500 Hz in 15-minute
cycles.
Frequency change permitted: ±0.0004 percent.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±0.0005 percent.
Reference documents. In addition to MIL-PRF-3098, this document references the following:
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business