MIL-PRF-3098/73E
REQUIREMENTS
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50 MHz to 134 MHz, inclusive.
Capacitance, shunt: 7 pF, maximum.
Mode of oscillation: Fifth mechanical overtone.
Rated drive level: 1.0 mW, maximum.
Calibration values:
Resistance: 60 ohms.
Voltage drop: 0.35 volt.
Resonance: Series.
Operating temperature range (noncontrolled): -30C to +71C, inclusive.
Frequency tolerance: 15 parts per million (ppm).
Equivalent resistance:
50 MHz to 90 MHz: 50 ohms, maximum.
90+ MHz to 134 MHz: 60 ohms, maximum.
Shock:
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Vibration: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Temperature cycling:
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Aging:
Frequency change permitted: 5 ppm.
Referenced documents. In addition to MIL-PRF-3098, this document references the following: