MIL-PRF-3098/53M
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 16 MHz to 61 MHz, inclusive.
Capacitance, shunt: 3.5 pF, maximum.
Frequency tolerances:
Primary (operating temperature range): ±20 parts per million (ppm).
Secondary (operating temperature range): ±30 ppm.
Equivalent resistance: 40 ohms, maximum.
Mode of oscillation: Third mechanical overtone.
Temperature ranges:
Primary: -40°C to +90°C, inclusive.
Secondary: -55°C to -40°C and +90°C to +105°C, inclusive.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Unwanted modes: Twice main mode.
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration high frequency: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
3