MIL-PRF-3098/52H
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50.0 MHz to 125 MHz, inclusive.
Frequency tolerance:
Operating temperature range: ±10 parts per million (ppm).
Room temperature: ±70 ppm.
Equivalent resistance: ±40 ohms, maximum.
Mode of oscillation: Fifth mechanical overtone.
Reference temperature: +75°C ±1°C.
Temperature ranges:
Operable temperature range: -55°C to +70°C and +80°C to +90°C, inclusive.
Operating temperature range (controlled): +70°C to +80°C, inclusive.
Drive level: 1.0 mW maximum.
Resonance: Series.
Capacitance, shunt: 7.0 pF, maximum.
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 201 of MIL-STD-202.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
3