MIL-PRF-3098/45K
REQUIREMENTS
Dimensions, marking, and configuration: See figure 1.
Frequency range: 17 MHz to 62 MHz, inclusive.
Capacitance, shunt: 7 pF, maximum.
Mode of oscillation: Third mechanical overtone.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Calibration values:
Resistance: 40 ohms.
Resistor voltage drop: 0.28 volt.
Operating temperature range (noncontrolled): -55°C to +105°C, inclusive.
Frequency tolerance: ±25 parts per million (ppm).
Equivalent resistance: 40 ohms, maximum.
Shock:
Frequency change permitted: ± 5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: ± 5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
3