MIL-PRF-3098/42K
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 2.4 MHz to 20 MHz, inclusive.
Frequency tolerance:
Operating temperature range: ±50 parts per million (ppm).
Antiresesonace, load capacitance: 30.0 pF ±0.5 pF.
Equivalent resistance: See table I.
Operating temperature range (noncontrolled): -55°C to +105°C, inclusive.
Mode of oscillation: Fundamental.
Rated drive level: 1.0 mW, maximum.
Capacitance, shunt: 2.4 MHz to 4.0 MHz - 1.7 pF min. to 7.0 pF max.
4.0 MHz to 6.0 MHz - 2.7 pF min. to 7.0 pF max.
6.0 MHz to 20.0 MHz - 3.7 pF min. to 7.0 pF max.
Shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
3