MIL-PRF-3098/41J
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 200 kHz to 555 kHz, inclusive.
Frequency tolerances:
Primary operating temperature range: ±100 parts per million (ppm).
Second operating temperature range: ±150 ppm.
Equivalent resistance: See table II.
Mode of oscillation: Fundamental.
Antiresonance, load capacitance: 20.0 pF ±0.5 pF.
Operating temperature ranges (noncontrolled):
Primary: -40°C to +70°C, inclusive.
Secondary -55°C to -40°C, inclusive and +70°C to +90°C, inclusive.
Rated drive level: 1.0 mW, maximum.
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±15 percent.
Vibration: Method 204 of MIL-STD-202, test condition A, .060 inch total excursion, 10 Hz to 55 Hz;
amplitute to produce 5 gravity units, 55 Hz to 500 Hz.
Frequency change permitted: ± 5ppm.
Equivalent resistance change permitted: ±15 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±15 percent.
Bond strength: See table I.
3