MIL-PRF-3098/38H
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 5 MHz to 20 MHz, inclusive.
Capacitance, shunt: 7 pF, maximum.
Frequency tolerance (operating temperature range): ±50 parts per million (ppm).
Equivalent resistance: See table I.
Mode of oscillation: Fundamental.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Operating temperature range (noncontrolled): -55°C to +105°C, inclusive.
Shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
3