MIL-PRF-3098/37K
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50 MHz to 125 MHz, inclusive.
Capacitance, shunt: 7 pF, maximum.
Frequency tolerance:
Operating temperature range: ±20 parts per million (ppm).
Room temperature: ±80 ppm.
Frequency stability: ±5 ppm.
Equivalent resistance: 50 MHz to 100 MHz: 50 ohms, maximum.
100+ MHz to 125 MHz: 60 ohms, maximum.
Mode of oscillation: Fifth mechanical overtone.
Reference temperature: +85°C ±1°C
Temperature ranges:
Operating (controlled): +80°C to +90°C, inclusive.
Operable: -55°C to +80°C, inclusive.
Calibration values:
Resistance: 60 ohms.
Resistor voltage drop: 0.24 volt.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Shock:
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 201 of MIL-STD-202.
Frequency change permitted: ±5 ppm
Equivalent resistance change permitted: ±10 percent
3