MIL-PRF-3098/21H
TABLE I. Capacitance, shunt.
Frequency range,
Capacitance
inclusive
pF 1/
kHz
450 + 1.2
90 to 170
f
322 + 1.2
170+ to 250
f
1/ The letter "f" represents specified frequency in
kHz. A capacitance tolerance of ±15% is
permitted.
Part or Identifying Number (PIN): CR42/U (followed by specified frequency), see 1.2 of MIL-PRF-3098.
Referenced documents. In addition to MIL-PRF-3098, this document references the following:
The margins of this specification are marked with vertical lines to indicate where changes from the
previous issue were made. This was done as a convenience only and the Government assumes no
liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to
evaluate the requirements of this document based on the entire content irrespective of the marginal
notations and relationship to the last previous issue.