MIL-PRF-3098/17G
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 90 kHz to 250 kHz, inclusive.
Capacitance, shunt: See table I.
Frequency tolerance:
Operating temperature range: �200 parts per million (ppm).
Equivalent resistance: 90 kHz to 170 kHz: 5,000 ohms, maximum.
170+ kHz to 250 kHz: 5,500 ohms, maximum.
Mode of oscillation: Fundamental.
Antiresonance, load capacitance: 20.0 pF �0.5 pF.
Operating temperature range (noncontrolled): -40�C to +70�C, inclusive.
Rated drive level: 1.0 mW, maximum.
Shock (specified pulse):
Frequency change permitted: �10 ppm.
Equivalent resistance change permitted: �15 percent.
Frequency change permitted: �10 ppm.
Equivalent resistance change permitted: �15 percent.
Temperature run:
Frequency change permitted: �10 ppm.
Equivalent resistance change permitted: �15 percent.
Bond strength: 90 kHz to 170 kHz: 800 grams, minimum
170+ kHz to 250 kHz: 700 grams, minimum
TABLE I. Capacitance, shunt.