MIL-PRF-3098/146D
Capacitance, shunt:
2.4 MHz to 4.0 MHz: 1.7 pF minimum to 7.0 pF maximum.
4.0 MHz to 6.0 MHz: 2.7 pF minimum to 7.0 pF maximum.
6.0 MHz to 20.0 MHz: 3.7 pF minimum to 7.0 pF maximum.
Shock (specified pulse):
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Vibration: Method 204 of MIL-STD-202, test condition A.
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Temperature cycling:
Frequency change permitted: 5 ppm.
Equivalent resistance change permitted: 10 percent.
Aging:
Frequency change permitted: 5 ppm.
Part or Identifying Number (PIN): CR165/U (followed by specified frequency), see 1.2 of MIL-PRF-3098.
Reference documents. In addition to MIL-PRF-3098, this document references the following:
The margins of this specification are marked with vertical lines to indicate where changes from the
previous issue were made. This was done as a convenience only and the Government assumes no
liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to
evaluate the requirements of this document based on the entire content irrespective of the marginal
notations and relationship to the last previous issue.