MIL-PRF-3098/104F
REQUIREMENT:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50 MHz to 125 MHz, inclusive.
Frequency tolerance: ±25 ppm.
Equivalent resistance: 50 MHz to 90 MHz: 50 ohms, maximum.
90 MHz to 125 MHz: 60 ohms, maximum.
Mode of oscillation: Fifth overtone.
Operating temperature range (noncontrolled): -55°C to +105°C, inclusive.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Capacitance, shunt: 7 pF, maximum.
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock:
Frequency change permitted: ±5 ppm.
Equivalent-resistance change permitted: ±10 percent.
Vibration: Method 204, MIL-STD-202, test condition B.
Frequency change permitted: ±5 ppm.
Equivalent-resistance change permitted: ±10 percent.
Aging:
Frequency change permitted: ±5 ppm.
Reference documents. In addition to MIL-PRF-3098, this document references the following:
The margins of this specification sheet are marked with vertical lines to indicate where changes from the
previous issue were made. This was done as a convenience only and the Government assumes no
liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to
evaluate the requirements of this document based on the entire content irrespective of the marginal
notations and relationship to the last previous issue.