MIL-PRF-3098/100E
REQUIREMENTS:
Dimensions, marking, and configuration: See figure 1.
Frequency range: 50 MHz to 125 MHz, inclusive.
Capacitance, shunt: 4.5 pF, maximum.
Frequency tolerances:
Operating temperature range: ±10 ppm.
Reference temperature: ±10 ppm.
Room temperature: ±80 ppm.
Frequency stability: ±2.5 ppm.
Mode of oscillation: Fifth mechanical overtone.
Rated drive level: 1.0 mW, maximum.
Resonance: Series.
Reference temperature: +85°C ±1°C.
Temperature ranges:
Operating (controlled): +80°C to +90°C, inclusive.
Operable: -55°C to +80°C and +90°C to +100°C.
Equivalent resistance: 60 ohms, maximum.
Unwanted modes: Minimum unwanted mode effective resistance of 120 ohms or an unwanted to main
mode resistance ratio of 3:1, whichever is greater.
Shock (specified pulse):
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Vibration: Method 204, MIL-STD-202, test condition A; 0.06 inch double amplitude or 5 gravity units,
whichever is less.
Frequency change permitted: ±5 ppm.
Equivalent resistance change permitted: ±10 percent.
Thermal shock: ±10 ppm.
Aging:
Frequency change permitted: ±5 ppm.
Reference documents. In addition to MIL-PRF-3098, this document references the following: